F152

Channel Errors

Beckhoff · AX5000 Servo Drive

What does F152 mean?

This error indicates a problem within one of the drive's channels. If it's the only error displayed on a two-channel device, the fault likely lies in the other channel, requiring focused troubleshooting there. Otherwise, it's a general channel error necessitating further investigation based on other active diagnostic messages. This fault can also be a secondary error stemming from an incorrect P-0-0150 setting, often accompanying F4A5, preventing proper operation.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    If F4A5 (SoE Communication Parameter Error) is also present, investigate and correct issues related to parameter P-0-0150 first, as F152 might be a consequence of that primary error.

Source: Beckhoff AX5000 Servo Drive