4011

Group identifier not allowed

Beckhoff · TwinCAT 2 NC

What does 4011 mean?

An unacceptable value (outside the range of 1 to 255) has been used for a group identifier, or the specified group does not exist within the current system configuration. This parameter error prevents proper identification and control of the specified group of axes, leading to failure of coordinated motion commands.

Complete Troubleshooting Guide

  1. 1

    Verify the group ID parameter in the NC configuration. Ensure it is a unique value between 1 and 255.

  2. 2

    Confirm that the group with the specified ID actually exists and is properly configured in the system.

  3. 3

    Correct any misspellings or incorrect numerical entries for the group identifier.

  4. 4

    Restart the NC system after making configuration changes.