4470
SSI transformation fault or not finished
Beckhoff · TwinCAT 2 NC
What does 4470 mean?
The Synchronous Serial Interface (SSI) transformation performed by the FOX 50 module was either faulty for several NC cycles or failed to complete. This indicates a problem in reading or converting data from SSI encoders, leading to inaccurate or missing position feedback and ultimately affecting axis control.
Complete Troubleshooting Guide
- 1
Check the SSI wiring between the encoder and the FOX 50 module for integrity, shielding, and proper termination.
- 2
Verify the configuration of the FOX 50 module in the NC system, ensuring correct SSI parameters (e.g., clock frequency, data length).
- 3
Inspect the FOX 50 module itself for any diagnostic LEDs or fault indicators.
- 4
If connectivity and configuration are correct, consider replacing the FOX 50 module.