4507
Following error filter time (position) not allowed
Beckhoff · TwinCAT 2 NC
What does 4507 mean?
The value configured for the following error filter time (position) is not allowed, as it must be within the range [0.0, 600.0] seconds. This parameter filters out high-frequency noise from the following error signal, preventing nuisance trips. An invalid filter time can lead to either excessive false alarms or a failure to detect real errors.
Complete Troubleshooting Guide
- 1
Verify the following error filter time (position) parameter in the NC configuration for the controller.
- 2
Ensure the value is within the allowed range of 0.0 to 600.0 seconds.
- 3
Adjust the filter time to effectively smooth the following error signal without introducing excessive lag.
- 4
Save configuration changes and restart the NC system.