FB MUTING Bit 4

Muting EDM Monitoring Error - EDM1

Beckhoff · TwinSAFE Logic FB

What does FB MUTING Bit 4 mean?

An External Device Monitoring (EDM) error has been detected for the EDM1 feedback loop of the FB MUTING. This indicates a fault in the external safety output circuit (e.g., safety contactors) or its feedback path, which should confirm that the outputs have switched correctly in response to a muting event. This prevents unsafe operation if the outputs fail to respond, leading to a safety stop.

Complete Troubleshooting Guide

  1. 1

    Check the wiring of the EDM1 feedback loop, ensuring it is correctly connected to the safety contactor/relay monitoring contacts.

  2. 2

    Verify the functionality of the safety contactor/relay associated with EDM1; ensure contacts are opening/closing as expected and are not sticking.

  3. 3

    Review the EDM monitoring time parameter in the FB MUTING configuration; adjust if the contactor's switching time legitimately requires more time.

  4. 4

    Measure the voltage across the EDM input to verify the feedback signal's state during activation and deactivation of the monitored device.