FB TWOHAND Bit 1

Two-Hand Discrepancy Error - Input Pair 2

Beckhoff · TwinSAFE Logic FB

What does FB TWOHAND Bit 1 mean?

A discrepancy has been detected within the two channels of input pair 2 for the FB TWOHAND. This means the redundant hand actuation signals are not synchronizing correctly, indicating a potential issue with the two-hand device, its wiring, or incorrect timing. This will prevent safe two-hand operation and put the machine into a safe state.

Complete Troubleshooting Guide

  1. 1

    Inspect the wiring of input pair 2 from the two-hand control device, ensuring both channels are correctly connected and free from damage.

  2. 2

    Verify the functionality of the pushbuttons or sensors for input pair 2; ensure they actuate simultaneously and reliably.

  3. 3

    Review the discrepancy time parameter for input pair 2 in the FB TWOHAND configuration; adjust if slight timing variations are acceptable for the application.

  4. 4

    Instruct the operator to actuate the two-hand control correctly and simultaneously, observing their technique.