xxxx 0101

Watchdog Time Elapsed

Beckhoff · TwinSAFE Logic FB

What does xxxx 0101 mean?

The FSoE watchdog timer on a device has expired, meaning that a safety telegram was not received within the configured watchdog period. This indicates a communication timeout, potentially due to network delays, device malfunction, or disconnection, leading to a safe state.

Complete Troubleshooting Guide

  1. 1

    Check the physical network connection (Ethernet cables, connectors) to ensure continuity and reliability.

  2. 2

    Verify the FSoE watchdog time parameter is appropriately set for the network latency and device cycle times.

  3. 3

    Monitor network load and traffic to identify any bottlenecks or excessive delays that could cause timeouts.

  4. 4

    Inspect the FSoE master and slave devices for operational status, power supply issues, or internal errors that could prevent telegram transmission.