F2819

Mains failure

Bosch Rexroth · IndraDrive MPx02

What does F2819 mean?

A complete loss of the AC mains input power supply has occurred. The drive is no longer receiving power from the grid, which means it cannot operate and will initiate a controlled shutdown. This fault indicates that the entire power source is interrupted, not just a single phase.

Common Causes

  • Main circuit breaker tripped or opened
  • Complete power outage on the supply line
  • Emergency stop activated, cutting main power
  • Loose or disconnected main power supply cable
  • External fault device (e.g., ground fault interrupter) tripped

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify the status of the main circuit breaker, fuses, or upstream contactor that supplies power to the drive and confirm it is closed/active.

  2. 2

    Measure the incoming AC mains voltage directly at the drive's input terminals (L1, L2, L3) and confirm it matches the nominal supply voltage specified for the drive.

  3. 3

    Inspect all incoming power cables, terminal blocks, and connections from the main power source up to the drive's input terminals for any signs of damage, loose connections, or disconnections.

  4. 4

    Check for any plant-wide power outages, local emergency power-off activations, or tripped main distribution board breakers that could affect the entire system or power branch supplying the drive.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02