Übersetzen...
FB TWOHAND Bit 9

Two-Hand Discrepancy Error - Pair 2 (Safe Inputs Active)

Beckhoff · TwinSAFE Logic FB

Was bedeutet FB TWOHAND Bit 9 ?

Similar to 'FB TWOHAND Bit 1', but specifically when the 'Safe Inputs after Disc Error' option is active for input pair 2. This means a discrepancy occurred, and although the FB is attempting to maintain a safe state for the inputs, the error persists, indicating a critical issue with the input pair that requires immediate attention and prevents operation.

Häufige Ursachen

  • Intermittent contact or open circuit in the wiring connecting input pair 2 to the safety module (e.g., terminals X5.1, X5.2).
  • Mechanical failure or contamination within the actuation mechanism of the two-hand button for input pair 2.
  • Inadequate electrical isolation for input pair 2, leading to external noise coupling onto signal lines.
  • Loose terminal connections for input pair 2 on the safety PLC or at the button enclosure.
  • Safety module input channel failure specific to one channel of input pair 2.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    1. Verify secure connections at all terminals for input pair 2, from the buttons to the safety input module (e.g., X5.1, X5.2).

  2. 2

    2. Actuate the buttons for input pair 2 and use a multimeter to verify consistent voltage levels (e.g., 24VDC active) at the respective safety input terminals.

  3. 3

    3. Isolate and test the individual pushbuttons for input pair 2 for proper contact operation (NO/NC state changes) using a continuity tester.

  4. 4

    4. If suspected EMI, ensure signal cables for input pair 2 are routed away from power cables and proper shielding is maintained.

  5. 5

    5. After addressing the discrepancy, perform a forced safety system reset (e.g., acknowledge fault via HMI or dedicated input) to clear the 'Safe Inputs Active' state.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes