Was bedeutet SP0027 ?
The position coder (encoder) feedback cable is disconnected or the sensor is faulty. This results in loss of position feedback, making position control impossible.
Häufige Ursachen
- Position encoder cable is physically disconnected.
- Encoder signal lines are damaged.
- The encoder itself has failed.
- Incorrect encoder type configured in CNC.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check physical connection of the encoder cable at both the motor and the amplifier.
- 2
Measure encoder signal integrity (e.g., A, B, Z pulses) at amplifier terminals.
- 3
Verify encoder resolution and type settings in CNC parameter P4-XX.
- 4
Test encoder output using an oscilloscope if possible.