SP0220

Serial Spindle Amplifier Disconnected (15i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Was bedeutet SP0220 ?

The cable connected to the serial spindle amplifier for Series 15i is disconnected, or no serial spindle amplifier is connected. This prevents communication and control of the spindle.

Häufige Ursachen

  • Serial spindle amplifier disconnected or not communicating (15i).
  • Loss of communication with the spindle drive.
  • Spindle amplifier not powered or faulty.
  • Wiring problem on the serial communication link to the spindle amplifier.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the serial communication cable connection between the CNC and the spindle amplifier.

  2. 2

    Confirm that a serial spindle amplifier is physically connected to the system for Series 15i.