SP1226
Framing Error (CNC-Spindle, 30i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Was bedeutet SP1226 ?
A framing error occurred in communication between the CNC and the serial spindle amplifier for Series 30i. This typically indicates a mismatch in communication protocol or timing parameters.
Häufige Ursachen
- Data framing error in serial communication between CNC and spindle amplifier (30i).
- Incorrect start or stop bits configuration in serial communication settings.
- Data bits misalignment due to incorrect baud rate or bit timing.
- A faulty UART on either the CNC or the spindle amplifier.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify serial communication parameters (baud rate, data bits, stop bits, parity) match on both ends.
- 2
Inspect the serial data signal integrity at the terminal block.
- 3
Ensure the serial connector is clean and properly seated.
- 4
Test the serial port functionality by using a loopback connector.