Übersetzen...
SP1227
Receive Error (CNC-Spindle, 30i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Was bedeutet SP1227 ?
A receive error occurred in communication between the CNC and the serial spindle amplifier for Series 30i. This indicates an issue with the data reception at the CNC or potentially corrupted incoming data.
Häufige Ursachen
- The spindle amplifier failed to correctly receive data from the CNC (30i).
- Corrupted data packets on the serial line.
- Intermittent connection issues on the serial communication path.
- A buffer overflow in the spindle amplifier's receive buffer.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the spindle amplifier's status register for specific receive error codes.
- 2
Verify the serial cable is securely connected at both the CNC and amplifier ends.
- 3
Measure the signal quality on the RXD line during communication.
- 4
Try communicating with a different serial device to isolate the issue.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters