Communication Error (CNC-Spindle Amplifier, 30i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Was bedeutet SP1228 ?

A general communication error occurred between the CNC and the serial spindle amplifier for Series 30i. This is a broad indication of communication failure, requiring further investigation into the communication link.

Häufige Ursachen

  • A general communication failure between the CNC and the serial spindle amplifier (30i).
  • Incorrect serial port configuration on either device.
  • The spindle amplifier is not powered on or is in a fault state.
  • A break in the serial communication line.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the serial port configuration parameters in the CNC (e.g., P71-01).

  2. 2

    Ensure the spindle amplifier has a stable power supply and no active fault indicators.

  3. 3

    Check for continuity on the serial communication wires.

  4. 4

    Try a different serial communication protocol if supported.