0233
Velocity Pulse Count Exceeded
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet 0233 ?
This invalid parameter setting alarm occurs when initialization bit 0 is set to 1, and the number of velocity pulses configured exceeds the maximum allowable value of 13100. This indicates an incorrect setup for velocity feedback, potentially leading to calculation overflows.
Häufige Ursachen
- Expected velocity pulses not received within the defined timeframe.
- Encoder signal interruption or degradation.
- Motor not rotating as expected.
- Excessive lag in velocity feedback loop.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Correct the number of velocity pulses in the relevant parameter so that its value is within 13100.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026