OVC

OVC Alarm

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet OVC ?

This alarm is issued when a specific condition related to the OVC bit is detected. It is generally associated with a temperature rise in the motor or amplifier, indicating a potential for overheating under current operating conditions or parameter settings.

Häufige Ursachen

  • Overcurrent alarm triggered by the system.
  • Motor draw exceeding permitted current limits (P04-15).
  • Mechanical overload or jam.
  • Incorrect motor parameter configuration.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify that standard values are set for parameters No. 1877, No. 1878, No. 1893, No. 2062, No. 2063, and No. 2065.

  2. 2

    If parameter settings are confirmed correct, increase the acceleration/deceleration time constant.

  3. 3

    Increase the programmed stop time period to help suppress temperature rise.