Übersetzen...
PW0011
SAFE I/O CROSS CHECK ERROR(PMC)
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet PW0011 ?
The PMC detected an error in the system-defined safe I/O cross-check function. This indicates a discrepancy in the monitored safe I/O signals critical for safety operation, which could lead to an unsafe state. A power cycle is required.
Häufige Ursachen
- Mismatched state between monitored safe I/O signals by PMC.
- Defective component connected to PMC safe I/O points.
- PMC internal processing error for safe I/O comparison.
- Intermittent connection or signal degradation on safe I/O lines.
- Incorrectly set safe I/O parameters in the PMC.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the status of each safe I/O channel on the PMC's diagnostic interface.
- 2
Measure voltage levels at PMC safe I/O terminals.
- 3
Verify parameter P1-17 (PMC Safe I/O Configuration) settings.
- 4
Examine physical wiring for all connected safe I/O devices.
- 5
Test PMC's safe I/O comparison logic by cycling monitored inputs.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc Alpha i Series Servo Amplifier