Übersetzen...
SV0366

PULSE MISS(INT)

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet SV0366 ?

A pulse error occurred on the built-in Pulsecoder, indicating that expected pulses were not detected. This impacts the accuracy of position feedback from the internal encoder.

Häufige Ursachen

  • Interference on the pulse signal lines of the built-in Pulsecoder.
  • Internal Pulsecoder encoder disk damage or slippage.
  • Faulty signal generation within the built-in Pulsecoder.
  • External noise affecting pulse signal integrity.
  • Incorrect pulse output configuration in servo parameters.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Measure signal amplitude on internal Pulsecoder output terminals.

  2. 2

    Inspect internal Pulsecoder encoder disk for scratches or misalignment.

  3. 3

    Test internal Pulsecoder signal generation with a known good replacement if possible.

  4. 4

    Filter incoming power to the servo drive to reduce noise.

  5. 5

    Verify parameter P1-01 (Encoder Pulse Output) matches system requirements.

Alle Codes in diesem Handbuch durchsuchen (101)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Alpha i Series Servo Amplifier