SV0476

ILLEGAL SPEED CMD. (SV)

Fanuc · Alpha i Series Servo Amplifier

Was bedeutet SV0476 ?

The servo detected that the commanded speed on the axis exceeded the safety speed (parameter No. 13821 to 13824, No. 13826 to 13829) during safety monitoring (when the safety check request signal (*VLDVx) is 0). This suggests an unsafe operating speed was commanded or detected, posing a potential safety risk.

Häufige Ursachen

  • The system received an invalid or out-of-range speed command.
  • The requested speed value is not permissible by the drive's configuration.
  • Parameter P100.1 (Max Speed) is set too low for the command.
  • A command from a higher-level controller is invalid.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Confirm that parameters No. 13821 to 13824 and No. 13826 to 13829 are set to appropriate safety speed values.

  2. 2

    Verify that the axis operation program ensures movement is performed within the defined safety speed limits.

  3. 3

    Check the status of the safety check request signal (*VLDVx) to ensure correct operation of safety monitoring.