Was bedeutet 12359 ?
A read request was initiated while another read request was already active for the same resource or file_id. This IO_STATUS error indicates an attempt to perform concurrent read operations which is not supported or allowed for the specific resource. The program will abort if the file_id is invalid.
Häufige Ursachen
- Program logic error attempting multiple reads on the same file_id concurrently without proper synchronization or completion checks.
- Failure to properly complete or close a previous read request before initiating a new one.
- The file_id used does not correspond to a valid opened file, leading to confusion in state management.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review KAREL program logic to ensure read requests are handled sequentially for a given file_id and resource.
- 2
Verify that previous read operations are fully completed and their results processed before initiating new ones on the same resource.
- 3
Use the KAREL command READ file_id(cr) to clear any existing IO_STATUS error condition.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc R-30iA R-30iB Controller