PROGRAM SIZE OVER
Fanuc · Series 0i-D/0i Mate-D Maintenance
Was bedeutet ER02 ?
This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that the sequence program (ladder program) is too large, exceeding the available memory for PMC operation. This makes the program invalid.
Häufige Ursachen
- The size of the sequence program exceeds the PMC's available memory capacity.
- The ladder step count option installed is insufficient for the program's size.
- Inefficient programming leading to an unnecessarily large program.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the sequence program and identify opportunities to simplify logic or remove redundant code to reduce its overall size.
- 2
Consolidate subprograms or macros to optimize memory usage where possible.
- 3
Verify the current PMC memory configuration and compare it against the program's requirements.
- 4
Confirm the specified ladder step count option matches the actual capacity of the PMC.
- 5
If further program reduction is not possible, contact FANUC support for guidance on obtaining a larger ladder step count option.