+ OVERTRAVEL ( SOFT 1 )
Fanuc · Series 0i-D/0i Mate-D Maintenance
Was bedeutet IE0001 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 1 on the positive side for an axis has been exceeded. This is a software limit violation.
Häufige Ursachen
- NC program error commanding movement beyond the positive software limit 1.
- Incorrect setting of the software limit parameter for positive stroke check 1.
- Manual operation or jog movement exceeding the defined positive software limit 1.
- Tool length offsets or work offsets are incorrectly applied, causing an apparent overtravel.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the NC program for coordinate values or movements that exceed the defined positive software limit 1 for the affected axis.
- 2
Verify the parameter setting for the positive software limit 1 for the specific axis, ensuring it is correctly configured.
- 3
Ensure that tool length offsets or work offsets are accurately entered and do not cause an overtravel condition.
- 4
In manual mode, jog the affected axis in the negative direction away from the limit, then reset the alarm.
- 5
Confirm that the machine's reference position (zero return) has been correctly established for the affected axis.