IE0005

+ OVERTRAVEL ( SOFT 3 )

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet IE0005 ?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 3 on the positive side for an axis has been exceeded. This is a tertiary software limit, typically used for complex tooling or specific safety zones.

Häufige Ursachen

  • NC program error commanding movement beyond the positive software limit 3.
  • Incorrect setting of the software limit parameter for positive stroke check 3.
  • Physical interference from tooling, workpieces, or machine components triggering the third soft limit.
  • Manual jog operation exceeding the defined positive software limit 3.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Examine the NC program for commands that result in the axis exceeding the positive limit of stored stroke check 3.

  2. 2

    Verify the parameter settings for stored stroke limit check 3 on the positive side for the affected axis.

  3. 3

    Inspect for any physical interference from tooling, workpieces, or machine components that trigger this third soft limit.

  4. 4

    Jog the axis in the negative direction to clear the overtravel condition and then reset the alarm.

  5. 5

    Ensure that the tool data and offset values are correctly entered and do not lead to an overtravel condition.