- OVERTRAVEL ( SOFT 3 )
Fanuc · Series 0i-D/0i Mate-D Maintenance
Was bedeutet IE0006 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 3 on the negative side for an axis has been exceeded. This is a tertiary software limit, typically used for complex tooling or specific safety zones.
Häufige Ursachen
- NC program error commanding movement beyond the negative software limit 3.
- Incorrect setting of the software limit parameter for negative stroke check 3.
- Physical interference from tooling, workpieces, or machine components triggering the third soft limit.
- Manual jog operation exceeding the defined negative software limit 3.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Examine the NC program for commands that result in the axis exceeding the negative limit of stored stroke check 3.
- 2
Verify the parameter settings for stored stroke limit check 3 on the negative side for the affected axis.
- 3
Inspect for any physical interference from tooling, workpieces, or machine components that trigger this third soft limit.
- 4
Jog the axis in the positive direction to clear the overtravel condition and then reset the alarm.
- 5
Ensure that the tool data and offset values are correctly entered and do not lead to an overtravel condition.