SW0100
PARAMETER ENABLE SWITCH ON
Fanuc · Series 30i/31i/32i-MODEL B Parameter
Was bedeutet SW0100 ?
This alarm is issued when bit 0 (PWE) of setting parameter No. 8900 is set to 1. This condition indicates that the parameter write enable switch is active, which is typically enabled only for parameter modification and should be disabled during normal machine operation to prevent unintended changes.
Häufige Ursachen
- Parameter 'PARAMETER ENABLE SWITCH' is activated.
- Software parameter protection is currently enabled.
- Security feature preventing parameter modification is active.
- Hardware switch for parameter enabling is in the ON position.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the state of bit 0 (PWE) of setting parameter No. 8900 — set it to 0 to disable parameter write enable.
- 2
Verify if the external reset signal is active — depending on the setting of bit #2 (PWR) of parameter No. 3117, an external reset may clear this alarm.