ArcContinuousFault
Fronius · Symo Advanced
Was bedeutet 1173 ?
An electric arc has been identified within the PV system, and the inverter has reached the maximum allowed number of automatic reconnections within a 24-hour period. This fault indicates a persistent arc condition requiring immediate investigation. The inverter's operating LED flashes red, signifying a critical issue that could lead to component damage or personal injury if not addressed.
Häufige Ursachen
- An electric arc has been continuously identified on the PV system.
- The maximum number of automatic connection attempts within 24 hours has been reached due to persistent arc fault detection.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Before confirming this status, thoroughly check the entire photovoltaic system for any possible damage and ensure all damaged components are repaired by qualified specialists.
- 2
Keep the sensor pressed on the inverter for 3 seconds (maximum 6 seconds) to attempt clearing the fault.
- 3
On the inverter's user interface, navigate to the System > Event Log menu area and confirm the status 1173 - ArcContinuousFault.
- 4
Alternatively, on the inverter's user interface, navigate to the Notifications user menu and confirm the status 1173 - ArcContinuousFault.