PV Input Current Asymmetry
Fronius · Symo Advanced
Was bedeutet 205 ?
This status code indicates an asymmetry in the PV input currents, specifically relevant for the Fronius Primo GEN24 208-240 inverter when multiple parallel strings are connected to a single MPPT. This can result from differing string characteristics, partial shading, or issues with individual modules.
Häufige Ursachen
- Different lengths or types of solar module strings connected in parallel.
- Partial shading affecting one or more parallel strings, leading to reduced current output.
- Malfunction of individual solar modules or entire strings, causing imbalanced current contribution.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the configuration of all solar module strings for consistent module types, number of modules, and equal string lengths.
- 2
Inspect the PV array for partial shading that might be affecting one or more parallel strings.
- 3
Measure the DC input currents of each individual string at the inverter's DC input terminals to identify the imbalanced string.
- 4
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the inverter may require service.