Übersetzen...
231-A001
Cancelation of brake-test call monitoring
Heidenhain · TNC CNC Controllers
Was bedeutet 231-A001 ?
This error indicates that the brake-test call monitoring was canceled. This typically happens if protective doors are opened during the brake test, or if the drive-ready signal is not present during the monitoring period.
Häufige Ursachen
- Protective door(s) were opened during the brake test.
- No drive-ready signal was present during the brake-test call monitoring.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Ensure all protective doors are closed and securely latched before and during the brake test.
- 2
Verify that the drive is ready (drive-ready signal is active) before initiating and throughout the brake-test call monitoring.
- 3
Check the status of safety door interlocks and associated sensors for correct operation.
- 4
Inspect wiring for protective door switches and drive-ready signal for integrity and proper connection.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Heidenhain TNC CNC Controllers