231-A003
SPLC commissioning mode active
Heidenhain · TNC CNC Controllers
Was bedeutet 231-A003 ?
This error indicates that the Safety PLC (SPLC) commissioning mode is still active. This happens when the CRC check of the SPLC program is deactivated (machine parameter CfgSafety --> commissioning is set), which is typically done during machine setup but must be deactivated before machine delivery for safe operation.
Häufige Ursachen
- CRC check of the SPLC program is deactivated (machine parameter CfgSafety --> commissioning is set).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Deactivate the commissioning mode by resetting the 'commissioning' setting in the machine parameter CfgSafety.
- 2
Verify that the CRC check of the SPLC program is enabled after deactivating commissioning mode.
- 3
Confirm that the machine is ready for production operation with all safety features active.