Übersetzen...
F644

Negative travel limit switch detected

Indramat · DIAX 04

Was bedeutet F644 ?

The DIAX04 SSE-03VRS drive has detected that the physical negative travel limit switch has been activated. This indicates the machine axis has reached the physical end of its travel in the negative direction. The drive faults to prevent overtravel and potential mechanical damage, even if software limits might still allow further movement.

Häufige Ursachen

  • Machine axis physically moved to the negative end of its travel, activating the limit switch.
  • Incorrectly configured negative software travel limits, allowing motion too close to the physical limit switch.
  • Faulty negative limit switch that is stuck in the active state or incorrectly wired to the DIAX04 SSE-03VRS drive.
  • Overshoot due to aggressive deceleration ramps or high inertia, causing the axis to hit the limit switch.
  • Mechanical adjustment of the limit switch is incorrect, placing it too early in the travel range.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Manually move the machine axis slightly back from the negative limit switch until it deactivates.

  2. 2

    Inspect the physical negative travel limit switch for any damage, misalignment, or mechanical obstruction that would cause it to activate prematurely.

  3. 3

    Verify the wiring of the negative limit switch to the DIAX04 SSE-03VRS drive for continuity, shorts, or incorrect connections.

  4. 4

    Check the mechanical adjustment of the limit switch. Ensure it is positioned correctly relative to the desired travel range.

  5. 5

    Review the negative software travel limit parameter (e.g., S-0-0050) in the DIAX04 SSE-03VRS drive to ensure it is set well within the physical limit to provide a buffer.