BCD Input
Indramat · ServoDyn D Servo Drive
Was bedeutet 16 ?
This error occurs if a BCD (Binary Coded Decimal) command is encountered in the CLM01.3-M user program, but the auxiliary inputs designated for BCD operation are not configured or wired to interpret data in BCD format.
Häufige Ursachen
- A BCD program command (e.g., BCA, BCB, BCD) is used without the corresponding auxiliary inputs being set for BCD interpretation.
- Auxiliary input configuration parameters are incorrectly set, expecting standard digital inputs instead of BCD.
- Wiring errors on auxiliary inputs 1 through 8 prevent proper BCD signal reception.
- Faulty BCD input device or sensor.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify that auxiliary inputs 1 through 8 are correctly configured and wired for BCD format if BCD program commands are used.
- 2
Review the relevant CLM01.3-M parameters that define the type and format of auxiliary inputs to ensure they match BCD requirements.
- 3
Inspect the wiring of auxiliary inputs 1 through 8 for any misconnections, loose terminals, or shorts.
- 4
If a BCD input device is used, check its functionality and output signals to ensure it is providing valid BCD data.
- 5
Modify the user program to either remove BCD commands if inputs cannot be configured for BCD, or correct the input configuration.