RS Break-Error
Indramat · ServoDyn D Servo Drive
Was bedeutet 27 ?
This error occurs if the optional IDS board is enabled via Parameter 80 (Serial Interface) but the CLM01.3-M fails to detect a physical connection to the IDS board. This indicates a communication or hardware issue with the IDS board.
Häufige Ursachen
- The IDS board is not physically connected or is improperly seated in its slot.
- The IKS 742 cable connecting the IDS board to CLM01.3-M connector X6 is defective or too long (max 10 meters).
- Parameter 80 (Serial Interface) is incorrectly configured to enable the IDS board when it is not present or not required.
- Faulty IDS board or CLM01.3-M serial communication port.
- Loose or damaged connections at CLM01.3-M connector X6.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the physical connection of the IDS board to CLM01.3-M connector X6, ensuring the IKS 742 cable is securely attached and undamaged.
- 2
Check the length and integrity of the IKS 742 cable; replace it if it is defective or exceeds the maximum recommended length of 10 meters.
- 3
Review Parameter 80 (Serial Interface) and disable the IDS board if it is not installed or intended for use.
- 4
Ensure the IDS board is properly seated in its slot within the CLM01.3-M chassis.
- 5
If the issue persists, contact Indramat Service Department as it may indicate a fault with the IDS board or the CLM01.3-M serial communication port.