Übersetzen...
MR5

Alarm Space 5 Violation

Kuka · KK53Y Servo Motor

Was bedeutet MR5 ?

The MR5 signal indicates a violation of monitoring space 5. A '0' state on this signal means that monitoring space 5 is currently being infringed upon. If monitoring space 5 is intentionally inactive, the system considers it violated by default, and the associated safe output MR5 will be in the '0' state.

Häufige Ursachen

  • Alarm condition triggered in Space 5 of the monitoring system.
  • Parameter P5 has exceeded its defined alarm threshold.
  • Sensor associated with Space 5 reporting an out-of-bounds value.
  • Configuration error in Space 5 alarm limits.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Identify the configured boundaries for monitoring space 5 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 5.

  3. 3

    If monitoring space 5 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR5 signal will default to a '0' (violated) state.

Alle Codes in diesem Handbuch durchsuchen (17)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes