Übersetzen...
26040

Heat sink temperature too high, KPP/KSP (axis)

Kuka · KR C4 Controller

Was bedeutet 26040 ?

This fault indicates an overtemperature condition on the heat sink of a KPP or KSP drive unit for an axis. Prolonged high temperatures can degrade component lifespan and lead to drive shutdown.

Häufige Ursachen

  • High ambient temperature around the cabinet
  • Excessive load in the robot program causing high heat generation
  • Dirt or obstruction in the cooling circuit of the drive
  • Blocked ventilation slits or insufficient clearance at the installation site

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check cabinet fan for proper operation and air flow.

  2. 2

    Measure ambient temperature around the KPP/KSP cabinet.

  3. 3

    Inspect cooling circuit for dirt or obstructions and clean as necessary.

  4. 4

    Verify installation site for adequate ventilation slits and clearance.

  5. 5

    Reinitialize the drive bus by cycling Power Off / Power On.

  6. 6

    Check the KSP module for any other anomalies.

Alle Codes in diesem Handbuch durchsuchen (21)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes