26048
Overvoltage during charging, KPP/KSP (axis)
Kuka · KR C4 Controller
Was bedeutet 26048 ?
This fault occurs when an overvoltage condition is detected during the charging phase of the KPP/KSP drive. This can be caused by an excessively high mains voltage or an insufficient number of connected capacitors, posing a risk to sensitive components.
Häufige Ursachen
- Mains voltage being too high
- Insufficient number of capacitors connected (too few modules) in the system
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the incoming mains voltage — verify it is within the specified operating range.
- 2
Verify the number of connected capacitor modules is adequate for the system configuration.
- 3
Reinitialize the drive bus by cycling Power Off / Power On.
- 4
Check the KPP module for any status indicators.
- 5
Check the KSP module (improbable).
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026