Übersetzen...
26105

Ground fault, KPP/KSP (axis)

Kuka · KR C4 Controller

Was bedeutet 26105 ?

This fault indicates a power unit overcurrent condition specifically due to a ground fault on an axis. It points to an insulation breakdown or unintended conductive path to ground in the motor or its cabling, leading to excessive current flow.

Häufige Ursachen

  • Insulation breakdown or damage in the motor cable, causing a short to ground.
  • Internal ground fault within the motor windings or housing.
  • Damaged components within the KPP or KSP causing a ground path.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Visually inspect the motor cable for insulation damage or signs of arcing.

  2. 2

    Measure insulation resistance of the motor cable between phases and to ground using a megger.

  3. 3

    Measure insulation resistance of the motor windings to ground.

  4. 4

    Reinitialize the drive bus by performing a Power Off / Power On cycle.

  5. 5

    Inspect KSP (KUKA SmartPAD) and KPP (KUKA Power Pack) for signs of damage or loose connections.

Alle Codes in diesem Handbuch durchsuchen (21)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes