Intermediate circuit charging failed, KPP/KSP (axis)

Kuka · KR C4 extended

Was bedeutet 26131 ?

This fault indicates that the intermediate DC link circuit failed to charge properly during power-up or initialization. This prevents the drive from starting or operating, pointing to a fundamental issue in the power supply path or the charging components.

Häufige Ursachen

  • Faulty intermediate circuit cabling.
  • Malfunction in the KSP module's charging circuit.
  • Malfunction in the KPP module's charging circuit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check intermediate circuit cabling for continuity and proper connections.

  2. 2

    Reinitialize the drive bus: Power Off / Power On.

  3. 3

    Check KSP module for faults related to charging.

  4. 4

    Check KPP module for faults related to charging.