Übersetzen...
26132

Collective brake fault, KPP/KSP (axis)

Kuka · KR C4 extended

Was bedeutet 26132 ?

The brake cable monitoring device has signaled a fault, such as a short-circuit, overcurrent, or a break in the connection. This fault affects all axes simultaneously, indicating a problem common to the braking system.

Häufige Ursachen

  • Fault in the brake voltage supply affecting all axes.
  • Motor or brake fault (short-circuit, overcurrent, no brake connected).
  • Brake cable or motor cable damage or improper connection.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the brake voltage supply for all axes.

  2. 2

    Inspect the motor and brake components (e.g., measure resistance of brake coil).

  3. 3

    Check brake cable and motor cable for damage, continuity, and proper connections.

  4. 4

    Reinitialize the drive bus: Power Off / Power On.

  5. 5

    Check the KSP module.

Alle Codes in diesem Handbuch durchsuchen (35)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes