LsrCellOrSafety- Error
Cell or laser safety error. Check safety equipment!
Kuka · LaserTech 3.1
Was bedeutet LsrCellOrSafety- Error ?
A general safety error has been detected within the robot cell or specific to the laser system. This indicates a breach or malfunction in the safety interlocks or protective devices.
Häufige Ursachen
- Interlock on laser cell access door is triggered.
- Emergency stop button within the laser area is activated.
- Safety light curtain or area scanner has detected an obstruction.
- Malfunction in laser safety interlock circuitry.
- Faulty safety limit switch on equipment housing.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Perform a thorough inspection of all cell safety equipment (e.g., doors, light curtains, emergency stops) and laser safety interlocks.
- 2
Identify and resolve the specific problem with the safety equipment (e.g., close safety gate, reset light curtain).
- 3
Acknowledge the message on the robot controller HMI.
- 4
Resume or restart the program.