MissingProcess- Gas

No process gas!

Kuka · LaserTech 3.1

Was bedeutet MissingProcess- Gas ?

The required process gas supply is either off, depleted, or not reaching the laser system at the required pressure. This prevents proper laser operation and affects process quality.

Häufige Ursachen

  • Process gas supply is interrupted or absent.
  • Low pressure detected in the process gas line.
  • Gas flow sensor failure or blockage.
  • Incorrect gas mixture detected.
  • Gas cylinder depleted or valve closed.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the process gas supply tank level and ensure all gas valves are open.

  2. 2

    Check the gas pressure at the laser system's input manifold.

  3. 3

    Acknowledge the message on the robot controller HMI.

  4. 4

    Resume or restart the program.