Übersetzen...
MT

Maintenance timer

Mitsubishi Electric · Mitsubishi FR-E800 Variable Frequency Drive

Was bedeutet MT ?

This indicator appears when the inverter's cumulative energization time reaches or exceeds the value set in parameter Pr.504. It serves as a reminder that routine maintenance may be due for the equipment.

Häufige Ursachen

  • Cumulative energization time has reached the threshold set in Pr.504 (Maintenance timer setting).
  • Environmental conditions (e.g., high temperature, dust) accelerate component wear, making maintenance due earlier than anticipated.
  • Cooling fan operating hours exceeding recommended service life.
  • Electrolytic capacitor aging approaching end-of-life.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Record the current operating hours displayed (e.g., Pr.504 related monitor value) for historical tracking.

  2. 2

    Inspect cooling fans for bearing noise, reduced airflow, or physical damage, and clean or replace if necessary.

  3. 3

    Clean inverter heatsinks and cooling passages to ensure optimal heat dissipation.

  4. 4

    Visually inspect electrolytic capacitors on the main circuit board for bulging or leakage.

  5. 5

    Reset Pr.504 (Maintenance timer setting) after completing maintenance tasks.

Alle Codes in diesem Handbuch durchsuchen (55)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Mitsubishi FR-E800 Variable Frequency Drive