5422 hex

Target Velocity Setting Out of Range

Omron · NJ/NX-series Motion Control

Was bedeutet 5422 hex ?

This error occurs when a motion instruction is executed without setting a valid target velocity, or if the set value is outside the acceptable non-negative range. The system requires a properly defined target velocity to initiate controlled motion.

Häufige Ursachen

  • The target velocity parameter was not explicitly set before executing the motion instruction.
  • An invalid value, such as a negative number or a value exceeding the controller's limits, was provided for the target velocity parameter.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify that the target velocity parameter is set to a non-negative numerical value before executing the instruction.

  2. 2

    Check the instruction's input variables to confirm the target velocity is correctly assigned and within operational limits.