Übersetzen...
5436 hex
Master and Slave Defined as Same Axis
Omron · NJ/NX-series Motion Control
Was bedeutet 5436 hex ?
This minor fault occurs when the Master Axis and Slave Axis are configured to be the same axis during an axis command instruction. This configuration leads to an execution condition error, preventing proper motion control operations.
Häufige Ursachen
- The Axis Variable specified for Master and Slave are identical in the instruction call.
- Incorrect axis assignment during the setup of the motion control instruction.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the Axis Variable specified for Master in the instruction is distinct from the Axis Variable specified for Slave.
- 2
Check the Axis Basic Settings in Sysmac Studio to ensure unique axis assignments for Master and Slave functions.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Omron NJ/NX-series Motion Control