CNC Instruction Re-execution Disabled
Omron · NJ/NY-series NC Integrated Controller
Was bedeutet 56030000 hex ?
This minor fault indicates that a CNC instruction, which is not designed for re-execution, was executed multiple times without proper sequence. The fault is detected at instruction re-execution and affects the CNC common part or a specific CNC coordinate system. This prevents the instruction from executing and stops the relevant CNC coordinate system immediately if it is in motion.
Häufige Ursachen
- An instruction that cannot be re-executed was called again while its `Busy` output variable was still TRUE.
- The `Execute` input variable for an instruction changed to TRUE before the previous execution of the same instruction had completed (i.e., `Busy` changed to FALSE).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Examine the CNC program logic for instructions that are re-executed without checking their completion status.
- 2
Modify the program to ensure the `Execute` input variable for an instruction only changes to TRUE when its `Busy` output variable from the previous execution is FALSE.
- 3
Implement logic to explicitly stop an instruction before attempting to execute it again if the instruction cannot be re-executed.