97800000 hex

Slave Error Code Report

Omron · NJ/NY-series NC Integrated Controller

Was bedeutet 97800000 hex ?

This informational event indicates that an error code was reported by a slave device following a Slave Error Detected (77860000 hex) event. The source is a CNC motor within the CNC Function Module. While the user program continues, the specific slave error may impact the CNC motor's operation, though the reporting event itself does not affect overall system operation. The actual slave error code is provided in the attached information.

Häufige Ursachen

  • A slave device (e.g., OMRON 1S-series or G5-series Servo Drive) has detected and reported an internal error.
  • A Slave Error Detected (77860000 hex) event has occurred, triggering this informational report.
  • The lower two digits of the attached information (e.g., FF13 indicates error 13) specify the detailed slave error.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Examine the attached information, specifically attached information 1 (Slave error code), to identify the reported slave error code.

  2. 2

    For OMRON 1S-series or G5-series Servo Drives, extract the lower two digits of the attached information to determine the main error display number (e.g., "13" from "FF13").

  3. 3

    Refer to the specific manual for the identified slave device (e.g., Servo Drive manual) using the extracted slave error code to troubleshoot and correct the root cause.