403
FIVE-MINUTE FULL FIELD
Otis · DSD 412 Elevator System
Was bedeutet 403 ?
This fault indicates that the Drive and Field Enable control circuit at terminal TB1-9 remained active for five minutes without the drive commencing operation. This condition can lead to burnout of the motor field winding.
Häufige Ursachen
- Issue with the car controller relay logic, incorrectly keeping the Drive and Field Enable active without a start command.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the car controller relay logic to ensure that the Drive and Field Enable signal at TB1-9 is not continuously active for prolonged periods without the drive being started.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026