923

LOAD CURRENT SETTING FAULT

Otis · DSD 412 Elevator System

Was bedeutet 923 ?

This fault is declared if a number entered for Rated Armature Current, #3, is outside the acceptable range of 0.125 to 2.0 times the bridge current rating. The bridge current rating is determined by the bridge sense resistor on the Cube ID PCB, located on the Armature Interface PCB. This fault requires a DSD power down.

Häufige Ursachen

  • Rated Armature Current parameter #3 set outside the acceptable range relative to the bridge current rating.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Enter a valid number for Rated Armature Current, #3, within 0.125 to 2.0 times the bridge current rating (determined by the Cube ID PCB sense resistor).