Übersetzen...
OHF
Drive overheating
Schindler · Altivar 312 Drive
Was bedeutet OHF ?
This fault indicates that the internal temperature of the drive has exceeded its safe operating limits. This can be due to high ambient temperature, inadequate ventilation, or excessive load.
Häufige Ursachen
- High ambient temperature around the drive.
- Excessive motor load causing the drive to work harder and generate more heat.
- Blocked or dirty cooling fan/heatsink on the drive.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the ambient temperature around the drive and ensure it is within specified operating limits.
- 2
Inspect the drive's cooling fan for proper operation and clean any dust or debris from the heatsink.
- 3
Reduce the motor load if it is consistently high, causing the drive to generate excessive heat.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Schindler Altivar 312 Drive