ABB · ACS850 Standard Program Firmware
An error has occurred while attempting to read position data over the Hiperface DSL interface. This suggests a problem with the feedback device wiring, the motor connector, or connections inside the adapter, which can lead to inaccurate or lost position information, affecting motor control and synchronization.
Click steps to track your progress.
Power down the drive, then visually inspect the Hiperface DSL cable for any physical damage or stress points along its length.
Using a multimeter, test for continuity and isolation between individual conductors of the Hiperface DSL cable.
Verify the Hiperface DSL cable's shielding is properly connected to ground at both the motor and the drive end (e.g., X14 terminal ground).
Confirm the Hiperface DSL cable wiring at the drive's X14 connector strictly follows the manufacturer's connection diagram (e.g., data+, data-, 24VDC, GND).
Check the drive's encoder configuration parameter (e.g., P5-01) to ensure 'Hiperface DSL' is correctly selected as the feedback type.
Monitor the drive's diagnostic parameters for encoder status (e.g., P5-05, P5-06) to identify specific communication errors or receive frames.