During velocity autotuning, the calculated test move velocity exceeds the configured `DriveSpeedMax` parameter. This indicates a mismatch between the desired tuning speed and the drive's maximum allowed operating speed, which can cause unsafe operation, tuning failures, or unexpected drive trips.
Click steps to track your progress.
Verify the DriveSpeedMax parameter (e.g., P1-05) setting against the motor's nominal speed and the application's actual maximum speed. Adjust P1-05 higher if appropriate.
Confirm the motor encoder resolution setting (e.g., P5-01, P5-02) accurately matches the encoder datasheet specifications.
Reduce the target test move velocity parameter (e.g., P2-10, P2-11) for autotuning to a value below the current DriveSpeedMax setting.
Monitor the motor's actual speed via drive diagnostic screen (e.g., P0-03) during a test move after parameter adjustments.
Temporarily increase the acceleration/deceleration ramps (e.g., P3-01, P3-02) for the tuning process to smooth speed transitions.